Welcome: HWTAI-Realiable Supplier of Medical Consumables
Info@Hwtai.com 008615867460640

Nitrofuran(SEM) rapid test dipsticks (Tissue)

The Nitrofuran(SEM) rapid test dipstick is based on competitive inhibition immuno-chromatographic principle. In the flow process, Nitrofuran(SEM) in the sample combined with Nitrofuran(SEM) specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Nitrofuran(SEM)-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Nitrofuran(SEM) residue or concentration lower than detection limit, T line is darker than C line or T line has same color with C line; when the concentration is equal to or higher than detection limit, T line is obviously lighter than C line or T line has no color. No matter whether there is Nitrofuran(SEM) residue in sample, C line will appear, it means the test is valid.

EMAIL

ba202105100943069791548横向.jpg

Introduction

1. Specifications

96 strips/kit

2. Brief

This product is used for testing Nitrofuran(SEM) in honey sample qualitatively. Easy to operate, high sensitivity.

3. Sample performance

Poultry and livestock tissue: pork, beef, sheep, chicken, duck, goose, and other tissue;

Fish, shrimp and crab: Freshwater fish, marine fish, shrimp, crab and other tissue.


4. Detection limit

Tissue:  0.5μg/kg( ppb)

5. Contents

1

Nitrofuran(SEM) test dipsticks Bottle(include test dipsticks, desiccant, micro-wells reagent)

12 Bottles

2

Manual

1 piece

3

1M HCl

2 Bottles

4

1M NaOH

2 bottles

5

1M K2HPO4 solution

2 bottles

6

Derivatization reagent

1 bottle

7

Sample buffer

2 bottles


6. Principle

The Nitrofuran(SEM) Rapid test dipstick is based on competitive inhibition immuno-chromatographic principle.p002.jpg In the flow process, Nitrofuran(SEM) in the sample combined with Nitrofuran(SEM) specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Nitrofuran(SEM)-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Nitrofuran(SEM) residue or concentration lower than detection limit, T line is darker than C line or T line has same color with C line; when the concentration is equal to or higher than detection limit, T line is obviously lighter than C line or T line has no color. No matter whether there is Nitrofuran(SEM) residue in sample, C line will appear, it means the test is valid.

7. Sample preparation

1) Take 5±0.05g homogenized tissue sample into 50ml centrifuge tube, add 4.5ml deionized water、1.5ml  Reagent A and 300ul Reagent B, shake and mix for 2min, put at 75℃ water bath for 5min;

2) Add 7ml Reagent C, shake and mix for 1min, add 6ml ethyl acetateshake and mix for 1min, centrifuge at 4000r/min for 5min;

3) Take 3ml up-layer liquid into a 10ml centrifuge tube, blow to dry at 75℃ by Nitrogen or air.

4) Add 1ml Reagent E, shake to dissolve the dry residue (if do not dissolve the residue completely, it may lead to the result unstable), then add 1ml Reagent F, shake to even for 30s, be stable until layered, absorb out the up-layer(if appear emulsion, centrifuge at 4000r/min for 5min);

5) Absorb 200ul down-layer liquid (water layer), ready to test. (Avoid absorb the up-layer liquid).

Note: The treated sample can be used for the detection of Nitrofurans(AMOZ, AOZ, AHD, SEM) at the same time.

8. Operation procedures

8.1 Read the instruction carefully before use. Return test dipsticks and sample into room temperature.

8.2 Take bottles needed from the kit package, take out required microwells and dipsticks, making proper marks. Please use these test dipsticks within 1h. Seal the cap of the bottles, avoid moisture.

8.3 Take 200ul of the test samples into the microwells, then slowly aspirate for 5-10 times, mix the sample with the reagent in the microwells completely until no solid judged by eyes (this is a very important step).

8.4 Incubate for 5min at room temperature (20-25℃) , then insert the test dipsticks into the microwells with the "MAX" end fully dipped in to the mixture solution.

8.5 Incubate for 5-8min at room temperature again, read the result, it is invalid in other time.

9. Test Result Interpretation

9.1 Negative: T line is darker than C line, or T line has same color with C line. It means there is no Nitrofuran(SEM) residue in sample or the residue is lower than detection limit.

9.2 Positive: T line is obviously lighter than C line or T line is invisible. It means the Nitrofuran(SEM) residue is equal to or higher than detection limit.

9.3 Invalidation: C line isn’t seen wine red. It means the test card is out of efficacy, out of date or improper operation. Please run the test again using another package. If the invalid tests keep happening, please contact the supplier.   



image.png

1688024295526.jpg


食品安全 2.jpg

INQUIRY

CATEGORIES

CONTACT US

Contact: Neo

Phone: 008615867460640

E-mail: Info@Hwtai.com

Whatsapp:008615867460640

Add: Building 2, Xinmao Qilu Science Technology Industrial Park, Tianqiao District, Jinan City, Shandong Province,China.