Welcome: HWTAI-Realiable Supplier of Medical Consumables
Info@Hwtai.com 008615867460640

Ovine Foot and Mouth Diseases Virus Anti-O Antibody Rapid Test

The Food and Mouth Disease rapid test for cattle FMDV-O Ab is a lateral flow immunochromatographic assay for the qualitative detection of serotype-O FMDV antibodies in cattle’s serum, plasma. VP1 protein recombinant was applied in this assay, for the monitoring of FMDV-O antibody level and providing an important reference for the vaccination plan. Assay Time: 5-10 minutes Specimen: serum, plasma.

EMAIL

11.jpg


Introduction


The Food and Mouth Disease Rapid test for cattle FMDV-O Ab is a lateral flow immunochromatographic assay for the qualitative detection of serotype-O FMDV antibodies in cattle’s serum, plasma. VP1 protein recombinant was applied in this assay, for the monitoring of FMDV-O antibody level and providing an important reference for the vaccination plan. Assay Time: 5-10 minutes Specimen: serum, plasma..


Product Name

Ovine Food and Mouth Disease Rapid test for  FMDV-O Ab

Specimen

Ovine's serum, plasma

Assay Time

5-10 minutes

MOQ

80 test kits

Delivery time

1 week after Get payment

Packing

10 test kits/Packing box

Storage Temperature

4-30°C, DO NOT FREEZE. Do not store the test kit in direct sunlight.

Shelf Life

18 months


Benefits

1. One-step whole blood, serum and plasma testing.

2. Simple operation, non-professional on-site inspection.

3. The detection process is fast, and the result will be displayed in about 15 minutes.

4. The test time is less than or equal to 10 seconds, and it can detect 270 samples per hour at the fastest.

5. The detection equipment is compact, easy to carry, mobile terminal operation, cloud platform quality control.

6. The detection sensitivity is high, comparable to that of enzyme-labeled kits.



Principle


The Food and Mouth Disease Rapid test for cattle FMDV-O Ab is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into the sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated FMDV-O antigens. If there are anti-O FMDV antibodies in the specimen, a visible T line will appears. The C line should always appear after a sample is applied, which indicates a valid result.



Components


• Test devices

• Droppers

• Single Buffer

• IFU


Strage and stablity

The kit can be stored at room temperature (2-30°C). The test kit is stable through the expiration date (18 months) marked on the package label. DO NOT FREEZE. Do not store the test kit in direct sunlight.

 



Other Items

Test Procedure

       Collect cattle’s fresh whole blood, and get the serum or plasma specimen for use. Immediately apply the testing once collected the specimen.

  • Take out the test device from the foil pouch and place it horizontally.

  • Place 2-3 drop (around 70-100uL) of serum or plasma specimen into the sample hole. Start timer and wait for result.

  • Interpret the result in 5-10 minutes. Result after 15 minutes is considered as invalid.



INTERPRETATION OF ASSAY RESULT